These terms refer to the same operating principle: a ported sphere rotates to open or shut off flow. The terms "ball valve" and "spherical plug valve" are also used. Specific models are further defined by their body construction, seat designs, and end connections.
MECA-INOX · VAMECA DISTRIBUTOR
3-piece stainless steel ball valves for steam, cold gas, and cryogenic applications. VAMECA delivers trusted local expertise across Quebec and Canada, assisting you in selecting the optimal seats, materials, and actuation solutions.

One design. Multiple configurations.
From three-piece bodies to distribution, isolation, and cryogenic applications.
3-Piece
Connection Selection and Maintenance
-196 °C
Cryogenic Extended Bonnet Designs
Quebec CRN
Designs registered in Quebec
ENGINEERED AROUND YOUR PROCESS
Your media and operating conditions dictate the right selection. Explore our engineered solutions, then compare the corresponding MECA-INOX product lines.
Corrosion-resistant

Standard stainless steel is not suitable for all aggressive media. MECA-INOX also delivers 904L and Alloy 22 constructions engineered to meet specific chemical resistance requirements.
Product Lines · PS4 U · 904L and PS4 H · Alloy 22
Technical Reference Guide Fluid composition and concentration, operating temperature, chloride levels, and compatibility of all wetted components.
Isolate steam or high-temperature media

PEEK and PEEK-filled seats expand operating capabilities for steam, superheated water, and thermal fluids. The PZ4 series features a 20% PEEK-filled PTFE seat, while the PP4 series utilizes solid PEEK.
Product Lines · PZ4 I · PP4 I · Flanged R2Z
Technical Reference Guide Operating temperature pressure, thermal cycling, differential pressure, and selected seat rating curve.
Cryogenic Service Operations

The PY4 I CY features a cryogenic extension that isolates the stem seal from the cold zone. Carbon-filled PTFE seats and body cavity relief are integral to this configuration specifically engineered for extreme low-temperature service.
Product Lines · PY4 / CY · PY4 / CYSF to fire safe requirements
Technical Reference Guide Gas or liquid media, minimum operating temperature, orientation, differential pressure, and cleanliness specifications. The cold gas PY4 I is not an automatic direct replacement for a PY4 I CY.
Facilitating Safe and Reliable Maintenance

A double block and bleed configuration combines two inline isolation points with an intermediate bleed. It allows for reliable verification and monitoring of the isolated section, fully aligned with the facility's system design and lockout/tagout procedures.
Product Lines · DBB on PS4 or PZ4 bases
Technical Reference Guide Pressure direction, connections, bleed accessibility, and isolation procedures. Selecting the right valve does not eliminate the need to validate the operating procedure.
Minimize retention areas

The selection focuses as much on geometry as it does on surface finish. Flush-mounted designs and bottom-tank valves minimize dead zones where media can accumulate. For clean utility applications, the PN4 features a low-ferrite ball paired with engineered surface finishes.
Product Lines · AFL · DR · FC / FCSZ · PN4 | For clean utilities
Technical Reference Guide True drainability, cleanability, materials of construction, surface roughness of wetted parts, and end connections. A standard PN4 valve is not, on its own, a zero-dead-leg valve.
Distribute or divert process fluids

L-port and T-port configurations enable precise flow path selection. The porting pattern and operating positions must be defined prior to selecting the actuator and its control system.
Product Lines · 3VLH · 3VTH · 3VLV per required flow pattern
Technical Reference Guide Open and closed positions, operating sequence, and pressure ratings for each port. The third port is not sealed in standard documented configurations.
Regulate flow

A V-port ball modulates the flow area during rotation. The 30° or 60° V-ball options are evaluated based on flow rate, pressure drop, and the positioning system.
Product Lines · PZ4 I V-Ball · PY4 I CY V-Ball
Technical Reference Guide Cv/Kv, minimum and maximum flow rates, differential pressure, cavitation or noise, and required precision. A standard on/off valve is not an engineered control solution.
Manufacturer Documentation · Materials

MECA-INOX EXPERTISE
MECA-INOX is a French manufacturer specializing in ball valves for industrial processes. Its modular design allows you to pair a standard valve body with seats, end connections, and actuation systems engineered specifically for your service conditions.
01 / MODULAR DESIGN
True sealing performance is engineered from within.
The three-piece body design provides easy access to internal components. The ball, seats, and stem sealing system form an engineered assembly selected specifically for your process media and operating cycles. The PS4, PZ4, PP4, PN4, and PY4 series are built to meet distinct application demands with dependable performance.

02 / THREE-WAY DIVERTER
The right flow path, in the right position.
An L-port or T-port configuration allows for diverting or distributing fluid flow. The 3VLH, 3VTH, and 3VLV designs differ by their flow path and mounting arrangement. Selecting the ideal configuration depends on your flow pattern, operating positions, and the required sealing performance across each port.

03 / DOUBLE BLOCK AND BLEED
Double block and bleed isolation.
DBB assemblies integrate two isolation components and a bleed valve to reliably monitor the intermediate zone. Configuration, bleed access, and differential pressure directions are carefully engineered to align with your lock-out/tag-out procedures and ongoing plant maintenance operations.

THE MECA-INOX PRODUCT LINES
This chart is designed to guide your selection of 3-piece stainless steel ball valves. Temperature ranges represent design reference limits and do not imply an allowable working pressure across all operating temperatures.
| Product Family | Primary Requirement | Seats | Reference Temperature¹ | Key Distinction |
|---|---|---|---|---|
| PS4 I | Compatible Process Isolation | 2nd-Generation PTFE | -50 to +190 °C | Versatile body design. End connections and materials selected based on the media. |
| PZ4 I | Steam and Thermal Fluids | PTFE + 20% PEEK | -30 to +280 °C | High-temperature service subject to the pressure-temperature rating curve. |
| PP4 I | Specific Seat Requirements | PEEK | 0 to +280 °C | Selection to be verified based on media compatibility and operating loads. |
| PN4 I | Clean Utilities and Surface Finish Requirements | 2nd-Generation PTFE · USP Class VI | -50 to +190 °C | Low-ferrite ball. Ra 0.4 µm / SF1 on ball and end connections, depending on configuration. |
| PY4 I | Cryogenic gases | Carbon-Filled PTFE | Gas < −50 °C² | Ball vented on the upstream side. Not to be confused with the CY version. |
| PY4 I CY | Cryogenic Fluids and Services | Carbon-Filled PTFE | -196 to +200 °C | Cryogenic extension bonnet. Allowable differential pressure depends on valve size. |
Scroll horizontally on smaller screens. ¹ Reference data from the “Body Lines” document, version 2025.06.16. ² The PY4 I is engineered specifically for cold gases in this documentation. The media, diameter, seals, pressure rating, and connection type govern the actual operational envelope.
Pressure ratings also vary depending on the valve size.
Documented example at −196 °C: the maximum differential pressure is 40 bar for the KY4 I CY, body sizes 010 to 050, and 10 bar for the CY4 I CY, body sizes 065 to 100. These limits do not supersede the pressure-temperature curve or the final configuration validation.
Materials and Seats
Identify the media, concentration, any present solids, and cleaning cycles. Validate the valve body, ball, seats, and seals.
Pressure Ratings and End Connections
Specify the NPS/DN, NPT or alternative standard threading, weld ends, or flanges, then verify the pressure-temperature rating curve at actual operating temperature.
Actuation & Automation
Select a manual lever, pneumatic actuator, or electric actuator. Specify torque requirements, fail-safe position, control signal, and accessories.
YOUR OPERATING ENVIRONMENT
Your industry dictates the specifications. Your media dictates the parameters. Explore both factors to configure the right solution for your application.
By Industry
The operational demands of your production environment.
By Application
Process media, operating temperature, and service conditions.
DOCUMENTATION & COMPLIANCE
VAMECA verifies the document scope for the proposed valve, its installation, and the applicable province. A CRN does not automatically cover all series or configurations.
QUEBEC · RBQ LICENSED
A technical specification package tailored to your province.
Select MECA-INOX designs are certified and registered for use in Quebec.
VAMECA cross-references your configuration against certified drawings and site installation requirements to ensure an exact fit.
Please specify the province, size, end connections, and operating conditions in your request.
Provinces and Configurations
The documentation reviewed confirms CRN coverage for Quebec. No Ontario registration has been confirmed by the manufacturer. For other provinces, specific sizes, materials, and end connections, our team will validate registration coverage before confirming the technical solution.
Testing and Traceability
The inspection and test plan (ITP), seat leakage testing, material test reports (MTRs), and specific testing reports must be requested upon configuration. Cryogenic testing to EN 1626 specified by the manufacturer applies specifically to designated cryogenic service designs.
Sanitary Standards and Fire-Safe Requirements
USP Class VI compliance for PN4 seats and ASME-BPE compliant designs must be distinguished from full valve certification. ISO 10497 fire testing applies specifically to designated models, notably the CYSF, and does not extend across all product lines.
FREQUENTLY ASKED QUESTIONS
YOUR DEDICATED TECHNICAL SPECIALIST
Commercial and technical support across Quebec and Canada to streamline your MECA-INOX product selection, procurement, and technical documentation.

SERVING QUEBEC AND CANADA
Need to replace an existing part or planning a new installation? Simply provide your media, pressure, temperature, and connection specifications. Our local technical experts will match them with the right manufacturer solutions.
AT EVERY STAGE OF YOUR PROJECT
Your project. A dedicated technical specialist.