Start with a clear photo of the rupture disc tag and its installation, or a purchase order reference. Include holder details, if applicable, along with the specified burst pressure and coincident temperature. Providing the quantity and required delivery date helps our team expedite your request. Submit your available specifications to connect with our local technical specialists.
OVERPRESSURE PROTECTION
Industrial Rupture Discs
SELECTION & REPLACEMENT

A rupture disc engineered for your installation and process conditions.
Part number · Connection type · Operating conditions
REPLACEMENT
Replace your rupture disc
Please provide a clear photo of the nameplate and installation, or an order reference number. Our technical team will assist you in gathering the necessary specifications for an exact replacement.
Diameter and pressure ratings alone are not sufficient to confirm interchangeability.
The Disc
Manufacturer, part number, and lot number, with burst pressure and temperature specified.
Assembly and Installation
Rupture disc holder (if applicable), diameter, connection type, and photos of the installation.
Reliable Service
Media, pressures, and temperatures. Please specify vacuum conditions, cycling, and any process variations.
Your Application Requirements
Quantity, required delivery date, and available documentation. In the event of premature opening, please include the operating conditions and circumstances.
UNDERSTANDING THE MECHANISM
How Does a Rupture Disc Work?
A rupture disc is a non-reclosing pressure relief safety device. Its membrane activates when the differential pressure reaches the engineered burst conditions at a specified temperature.
Upon opening, it clears the system's designated relief path. Following activation, the rupture disc must be replaced.
In technical documentation, you may also encounter the terms "disque d’éclatement," "rupture disc," or "bursting disc."
Burst Pressure and Temperature
Refer to both values indicated on the label or certificate.
Process Side
Discharge System →
01 Membrane
02 Porte-disque
03 Brides
Intact Disc
The diaphragm isolates the discharge path prior to actuation.
Simplified installation principle with rupture disc holder. Relief opening varies by model.
MAIN DESIGN CONFIGURATIONS
Forward or Reverse-Acting Rupture Discs
Two operating principles for dished designs, selectable based on your specific operating conditions.
TENSILE
Direct-Acting Disc
→ Pression du procédé
01 Membrane
In a domed construction, pressure acts on the concave side of the dome. The rupture disc is subjected to tensile stress until it bursts open.
Dished construction · concave side facing pressure
COMPRESSION
Reverse-Acting Rupture Disc
→ Pression du procédé
01 Membrane
Pressure acts on the convex side of the dome, causing it to reverse and trigger full opening as engineered.
Dished construction · convex side to pressure
Flat rupture discs as well as metal, composite, or graphite designs are available to meet specific application requirements. Certain models install directly between companion flanges without requiring a separate holder. For sanitary or hygienic service, please specify your connection and cleanability requirements.
Vacuum resistance and opening performance have been confirmed for the selected model.
CONFIGURE SELECTION
How to Select a Rupture Disc
Media, pressures, temperatures, and required discharge capacity drive the selection process. Submit your engineering specifications or get started with your available process data.
Pressure and Temperature Ratings
Burst pressure and associated temperature, equipment limits, followed by standard and maximum operating conditions. The service margin is verified for the selected model.
Fluids and Materials
Fluid type, concentration, and phase, as well as corrosion and buildup risks. This data guides the material selection for the disc, its seals, and any required support structure.
Thermal cycling, vacuum, and back pressure
Start-ups, shutdowns, pulsations, vacuum, and backpressure. Please also specify temperature fluctuations and any anticipated process changes.
Discharge and Connection
Overpressure scenario and required capacity (if available), NPS or DN size, end connection, and downstream conditions. Please also include any lift detection and documentation requirements.
Standards and Required Documentation
Do your technical specifications require specific standards or certifications? Please attach them to your request. Applicable documentation will be confirmed for both the device and its assembly.
ISO 4126-2 · Rupture Discs
ISO 4126-3 · Bursting Disc and Safety Valve Combinations
ASME BPVC
PROCESS PROTECTION
Rupture Disc or Pressure Relief Valve?
Both devices can contribute to overpressure protection; however, their post-activation response and system integration differ.
NON-RECLOSING
Rupture Disc
It opens once and remains open. The rupture disc must be replaced after activation.
RESEALING
Safety Relief Valve
It opens to discharge process media and reseats reliably once pressure returns to normal operating parameters.
A COMPLETE PRODUCT SELECTION
Combining a Rupture Disc with a Pressure Relief Valve
Installed upstream of a pressure relief valve, a rupture disc isolates the valve from corrosive media or process fluids that could foul its sealing surfaces.
The selection encompasses the complete assembly: rupture disc, holder, opening characteristics, safety valve, discharge capacity, and interspace monitoring.
YOUR TECHNICAL INQUIRIES
Rupture Discs: Frequently Asked Questions
VAMECA · QUEBEC & CANADA
Let's discuss your rupture disc requirements.
Whether you need a replacement part, are planning a new application, or need to verify a part number, let’s discuss your requirements using the specifications you have on hand.
Speak with Our Technical Specialists
Prepare My Request
Specify the part number or describe your application, then indicate the required quantity and delivery date.
To attach photos or technical drawings, please contact our team by email.