No. The PSCP energy storage reserve is an option. The motorized travel time of 6 to 20 s for 90° does not constitute a guaranteed failsafe return time.

Actuators in stock · Delivery within days on available items.

60–200 Nm adjustable
6–20 s for 90°
AMS2 Generation
IP67 standard
A programmable controller housed in an explosion-proof (Ex) enclosure
The brushless motor and Hall effect sensor deliver contactless drive and position tracking. The integrated positioner allows for precise stroke and control adaptation directly tailored to the valve.
Adjustable Torque
Cut-off torque adjustment from 60 to 200 Nm.
Adjustable Motorized Operating Time
Operating time of 6 to 20 seconds for a 90° rotation.
Integrated Positioning
Setpoint and feedback signals in 0/4–20 mA or 0/2–10 V.
Integrated Diagnostics
Tracking of starts, engine operating hours, and operational parameters.
Integrated Equipment and Standalone Options
All options and power supply specifications must match the certified assembly version.
PSQEX200AMS22
Integrated Equipment
A control platform engineered for quarter-turn modulating service.
Valve Positioner
Integrated
ISO 5211 Mounting
F07/F10
Protection
IP67
Service at 25°C
S2 30 min, S4 50%
The allowable average torque over the stroke is limited to 50% of the maximum torque specified in the data sheet.
Per configuration
Optional Configurations to Specify
Control, communication, and safety functions.
Local Sourcing and Orders
PSC.3
Power reserve
PSCP
Communications
Fieldbus communication depending on model
Enhanced Protection
IP68
Wi-Fi is listed as an option in the brochure. Availability must be confirmed based on your specific system configuration.
A technical dossier prepared with VAMECA
We help you align the configuration with your facility's specific operating requirements. Documentation references TÜV-A 25ATEX0103 X and IECEx BKI 25.0010X. The applicable certification must correspond to the markings on the supplied actuator.
Valves and Installation Requirements
Torque and Motion Control
Please specify the valve torque requirements, operating angle, and desired actuation time.
Flange and Shaft
Verify F07/F10 flange patterns, drive sleeve, coupling, and overall mounting dimensions.
Area Classification
Please provide the gas or dust group, temperature class, and ambient temperature.
Control and Electrical Specifications
Power Supply
The specification sheet covers 24 VAC/VDC, 100–240 VAC single-phase, or 200–440 VAC three-phase, depending on the model.
Control and Safety
Define signal, position feedback, communication protocol, and fail-safe behaviour.
Canadian Requirements
Verify site acceptance for the complete assembly. ATEX or IECEx certification alone does not constitute Canadian approval.
Share your valve specifications and hazardous area classification. VAMECA will identify available documentation, site-specific approval requirements, and lead times for the Ex configuration.
Configure the required functions
The documentation distinguishes standard functions from optional equipment.
PSCP Energy Reserve
The PSCP utilizes supercapacitors to return to a fail-safe position upon loss of power. This feature is optional.
Local Control and Interfaces
PSC.3, USB, and Wi-Fi—depending on equipment configuration—provide access to settings. All procedures must strictly comply with local hazardous area classifications.
Communications and Signalling
Field interfaces, a process controller, and configurable relays are available depending on the version.
PS Automation Technical Documentation
Complementary Product Lines
Evaluate motion, control, and fail-safe functionality before selecting your actuator.

OTHER PS AUTOMATION PRODUCT LINES
PS-AMS PSQ
Control a control valve with an integrated positioner, analog feedback, and diagnostic capabilities tailored to your operational requirements.
Discover PS-AMS PSQ →

OTHER PS AUTOMATION PRODUCT LINES
PSF-EX / PSF-M-EX
PS Automation actuators for explosive atmospheres, featuring either the PSF-EX spring-return fail-safe or the PSF-M-EX manual override. Hazardous area markings and mounting configurations are fully verified to match your plant's specific installation requirements.
Discover PSF-EX / PSF-M-EX →

ORDERING & OPTIONS
PS Automation Accessories
Analog control, position feedback, communication, or fail-safe functions. Explore key features and verify their compatibility with your PS Automation part number.
Explore PS Automation Accessories →