PS Automation Logo

PS Automation Accessories for Your Actuators

PS Automation Accessories for Your Actuators

PS Automation Accessories for Your Actuators

To add functionality or replace a module, VAMECA identifies accessories compatible with your actuator and specifies the exact components that can be integrated into your existing equipment.

To add functionality or replace a module, VAMECA identifies accessories compatible with your actuator and specifies the exact components that can be integrated into your existing equipment.

Actuators in stock · Delivery within days on available items.

PS Automation Accessories for Your Actuators

Analog Control

Position feedback

Communications

Electrical Safety

UNDERSTANDING THE PRODUCT LINE

UNDERSTANDING THE PRODUCT LINE

Add the exact functionality your facility requires

Accessories are selected using the complete actuator part number. The generation, power supply, and existing options determine mounting compatibility. VAMECA provides expert technical support for this verification across Quebec and Canada.

01

01

Order Now

Select an analogue input or interface engineered for seamless automation integration.

02

02

Monitor

Retrieve position, status, or fault feedback based on the installed equipment.

03

03

Provide on-site service

Access local control and configuration for compatible models.

04

04

Plan for isolation

Distinguish between a stored energy reserve and a standard override control input.

Which accessory for which application?

These compatibilities apply specifically to the documented product lines. They do not automatically extend to AMS2 generations or Ex-rated versions. Certain options must be specified at the time of ordering, notably PSCP, FSP, PSC.2, and communication buses on PSQ103/AMS1x models.

AccessoireFonctionFamillesRestrictions
PSAPAnalog PositionerPSL, PSQ, PSR-E-CPotentiometer required. Inputs compliant with PSAP.2A or PSAP.3
PSPT02 / PSPT03mA Position FeedbackPSL, PSQ, PSQ-E, PSR-EPotentiometer and external 24 VDC power supply required
2WETwo adjustable positionsDocumented Standard and PS-AMSStandard on PSQ-E and PSR-E25/50. Optional on PSR-E-C45.
2NDTorque IndicationStandard PQRLimited availability within this product line
RHAnti-condensation heaterDocumented Standard and PS-AMSConfiguration adapted to the power supply and enclosure
PSCS USBPC-Based ConfigurationPS-AMS PSL and PS-AMS PSQInterface and software engineered for generation
PSC.2Local Control and DisplayPS-AMS PSL and PS-AMS PSQSize-dependent mounting
Bus InterfacesControl and Data ExchangeDocumented PS-AMSModule selected according to protocol
psigProcess ControlDocumented PS-AMS PSL and PS-AMS PSQProcess sensor and configuration required
PSCPSupercapacitor BackupPS-AMS PSL and PS-AMS PSQNot compatible with FSP
FSPPriority Order EntryPS-AMS PSL and PS-AMS PSQNo stored energy capability. Incompatible with PSCP
FIRFault IndicationDocumented PS-AMSAlready integrated into select models, including the PSQ103/AMS1x

THE VAMECA ADVANTAGE: DEDICATED TECHNICAL SUPPORT

THE VAMECA ADVANTAGE: DEDICATED TECHNICAL SUPPORT

The Right Accessory for Your Actuator

You don't have to piece together the entire bill of materials on your own. Using the nameplate data and existing options, VAMECA helps you pinpoint the correct part number and determine whether a component can be field-retrofitted or must be factory-configured at the time of order.

Identify Existing Equipment

Complete Part Number

Please provide the model, serial number, and generation details.

Power Supply

Please specify voltage, frequency, and phase count.

Installed Options

Please attach the wiring diagram and part numbers for the installed modules.

Define Requirements

Desired Signal

Please specify the setpoint, position feedback, and communication protocol.

Safety Performance

Differentiate between power loss, signal loss, and manual override.

Environment

Specify ambient temperature, humidity, outdoor installation, and any hazardous location (Ex) requirements.

A clear photo of the nameplate and the required function are all we need to get started. Our technical team will confirm compatibility, installation requirements, and accessory availability.

Three Key Distinctions to Consider Before Ordering

Functions with similar names can serve very different operational requirements.

Safety

PSCP or FSP

PSCP stores energy to drive the actuator during a power outage. FSP receives an overriding command to move to a preset position. These two functions are incompatible.

Signal

Positioner or Transmitter

The PSAP receives a setpoint and controls the movement, while the PSPT transmits the position feedback to the automation system. Ensure the potentiometer and wiring match the selected configuration.

Field Service

Local or Manual Override

PSC.2 enables electric control and local configuration. The handwheel operates according to the actuator mechanism. Neither of these designations guarantees an energy reserve.

FAQ

FAQ

Inquiries Regarding Valve Accessories and Components

Inquiries Regarding Valve Accessories and Components