DEFINOX Logo

DEFINOX PEX / PEAX Sampling Valves

DEFINOX PEX / PEAX Sampling Valves

DEFINOX PEX / PEAX Sampling Valves

Sample directly from tanks or pipelines using a PEX or PEAX valve. Across Quebec and Canada, VAMECA provides the technical expertise to align your sampling method, cleaning procedures, and sealing selection with the exact configuration required for your operations.

Sample directly from tanks or pipelines using a PEX or PEAX valve. Across Quebec and Canada, VAMECA provides the technical expertise to align your sampling method, cleaning procedures, and sealing selection with the exact configuration required for your operations.

DEFINOX PEAX2 Two-Way Pneumatic Sampling Valve

Sampling Point

Manual PEX

Pneumatic PEAX

Single or double-acting

DEFINOX · PEX / PEAX

DEFINOX · PEX / PEAX

Selecting Sampling and Sterilization Solutions

PEX and PEAX valves are designed to draw product samples for quality control purposes. The selection process begins with the sterilization method, followed by product specifications, operating pressure during sampling, and connection type. VAMECA provides the technical expertise to help you identify the optimal configuration for your facility. Providing a photo of your existing valve alongside its part number also streamlines the identification of replacement diaphragms, discs, and other spare parts.

01

01

Manual or pneumatic actuation

PEX for manual operation. PEAX for integrating sampling into an automated sequence.

02

02

Two Sterilization Methods

Single-port configuration for flame applications or dual-port design for steam and cleaning solutions.

03

03

Application-Specific Sealing Solutions

Elastomer diaphragm or PFA disc available depending on sampling and cleaning conditions.

04

04

Multiple Connection Options

Select the fitting based on your existing tank or piping configuration and space accessibility constraints.

CONFIGURATION & SELECTION

CONFIGURATION & SELECTION

Configure sampling setup

The actuation method and number of flow paths represent two distinct design criteria. They do not substitute for verifying pressure ratings and sealing integrity.

Actuation and Sterilization

Manual PEX

Handle with travel stops. For flame sterilization, the manual specifies a stainless steel handle.

Automatic PEAX

Normally closed pneumatic actuator. Manual override lever and Sorio switch box available depending on configuration.

Versions 1 and 2

Single-port PEX1 and PEAX1 for flame applications. Two-way PEX2 and PEAX2 for steam or cleaning solutions.

Construction and Operating Conditions

Bodies and Seals

Single-piece 316L stainless steel body. Diaphragms available in VMQ, EPDM, FKM, or acid-resistant FKM. PFA disc paired with EPDM or FKM.

Sizes and End Connections

Sizes 6/8, 10/12, and 16/18. Available in welded, BSP/G thread, or clamp connections depending on the configuration. Please note that BSP/G threads are not compatible with NPT.

Sampling Pressure

The catalogue differentiates between static and dynamic ratings. Under dynamic conditions, limits range from 2 to 5 bar, depending on size and seal configuration. Relying solely on the 10-bar static rating is not sufficient for proper selection.

Need to replace or add a sampling valve? We will assess your mounting, actuation, and sealing requirements with you. A photo of your installation is all we need to get started, even without the complete part numbers.

OPERATION AND DOCUMENTATION

Integrating sampling into the process

Sampling procedures must account for product quality, operator accessibility, and the cleaning cycle.

Sterilization

Selecting the Right Method

Please specify the on-site procedure used. A configuration suitable for steam sterilization is not rated for continuous steam service.

Automation

Track PEAX status

The Sorio switch box complements pneumatic actuation with precise position feedback. The protocol is selected to integrate seamlessly with your control system.

Maintenance

Identify Wear Parts

Identify the model, size, and seal material prior to requesting replacement parts. Cleaning conditions are just as critical as the media being sampled.

Your DEFINOX Project, Supported by VAMECA

Our dual expertise in industrial valves and sealing solutions helps you pinpoint the exact valve and maintenance components you need. We liaise directly with the manufacturer to confirm pricing and lead times for your procurement. To get started, please share the details you have available below.

Product

Fluid to be sampled

Media characteristics, viscosity, and potential particulate content.

Terms and Conditions

Pressure during sampling

Static pressure, sampling pressure, and actual temperature.

Sterilization

Site Procedures

Flame, steam, or cleaning solutions, along with cycle conditions.

Assembly

Fitting and Actuation

Photo, existing part number, exact connection type, and manual or pneumatic actuation.

FAQ

Inquiries About PEX / PEAX

Inquiries About PEX / PEAX

Key technical guidelines for selecting and maintaining your industrial equipment.

Key technical guidelines for selecting and maintaining your industrial equipment.