PFA is offered as standard. EPDM or FKM variants are particularly well-suited for media containing solids or abrasive slurries. Selection must also account for process operating temperatures and CIP/cleaning chemicals.
An isolation check valve tailored to your process
The DCX3 opens or shuts off process flow in sanitary processing lines. Its one-piece plug comes standard with a floating PFA seal, engineered for easy surface cleaning and maintenance. The precision-machined spherical body is available in multiple configurations for seamless piping integration. Sub-assemblies are secured with sanitary clamp connections for quick, reliable servicing access. Valve selection also depends on the media handled, clean-in-place (CIP) cycles, and fail-safe position requirements upon loss of air supply. For direct replacements, nominal line size alone is insufficient: body geometry, end connections, seal materials, and actuator specifications must all be verified.
Gasket Cleaning
The floating PFA design allows cleaning fluid to circulate across the seal faces.
Configurable Valve Body
L-port, T-port, cross, and half-cross body configurations accommodate diverse piping layouts.
Selectable Sealing Options
PFA, EPDM, or FKM depending on the configuration. Media characteristics, particulate content, and cleaning procedures determine the optimal selection.
Maintenance Access
Clamp connections and a removable actuator provide easy access to sub-assemblies.
Configuration-defining options
Start with the function and end connections, then verify the sealing integrity and actual operating conditions.
Configurations to Compare
Standard or Long-Stroke
The extended stroke increases disc clearance to accommodate fibrous or fragile media.
Manual or pneumatic
Manual override, normally open, normally closed, or double-acting depending on configuration.
Aseptic Requirements
A diaphragm or steam barrier requires a dedicated configuration. A standard DCX3 is not sufficient to qualify an aseptic process.
Technical Benchmarks
Sizes and End Connections
DN 25 to 150 as standard, with select configurations available up to DN 250. Our catalogue also includes US sizing from 1 to 4 inches.
Materials
Standard 316L stainless steel body with a 304 stainless steel actuator. Seals and disc/plug to be specified based on your fluid media and cleaning requirements.
Pressure and Temperature
The catalogue specifies ratings up to 8 bar for PFA or elastomer linings, and 6 bar with a diaphragm. Temperature limits depend on the selected seal and whether operation is static or dynamic.
Need to replace a DCX3 or source replacement seals? Send us a photo and the nameplate details. Leveraging our valve and sealing expertise, we'll pinpoint the exact manufacturer part number required for your order.
OPERATION AND DOCUMENTATION
Ordering, Cleaning, and Replacement
Clear configuration labelling streamlines commissioning and simplifies future maintenance.
Set fail-safe position
Specify the valve's required fail-safe action upon loss of air supply. A Sorio control top can integrate both actuation control and position feedback, depending on the selected configuration.
Describe the complete lifecycle
Please specify the CIP chemicals, their concentrations, temperatures, and phase durations. Note that a transient sterilization temperature does not represent a continuous operating temperature.
Starting with Tagging and Identification
Record the valve tag number and take clear photos of the nameplate, valve body, and actuator. These details ensure our technical team can accurately identify and source the correct seals and replacement sub-assemblies.
Your DEFINOX Project, Supported by VAMECA
Our team is here to support your operations across Quebec and Canada, in English or French. We will help determine the precise valve or replacement parts required for your application, followed by confirmed pricing and delivery schedules to streamline your procurement. Feel free to share the details below, even if your technical specifications are still preliminary.
PRODUCT
Fluid Handling & Industrial Cleaning
Media characteristics, viscosity, potential particulates, and chemicals used during CIP (clean-in-place) cycles.
SERVICES
Pressure and Temperature
Normal and maximum operating conditions, including the specific phases during which the valve must cycle.
PIPING
Body and End Connections
Diameter, pipe standard, end connection type, L-port or T-port configuration, and available space.
AUTOMATION
Orders and Returns
Fail-safe position, available air supply, existing housing, and preferred communication protocol.
Additional Solutions for Your Process
Compare features and complete your system with other DEFINOX product lines.

FLOW CONTROL
DEFINOX DCX3 CONTROL VALVE
A profiled disc and positioner to precisely modulate flow according to process requirements.
Discover DCX3 REGUL →

DOUBLE SEAL
DEFINOX NEOS
A double-seal check valve with leak detection, specifically engineered for CIP (clean-in-place) systems.
Explore NEOS →

CONTROL AND INDICATION
Sorio Housings
Pneumatic actuation, position feedback, and seamless integration with your automated systems.
Discover Sorio →
FAQ