No. Liquid hydrogen requires specific engineering and qualification. The CXF and CCF data presented here do not qualify the valve for this service.
VINCO · Cryogenic Valves

CXF · Three-Piece
CXF · Three-Piece
CCF · Flanged
LNG · Liquid Nitrogen
COMPARE SERIES
Catalogue references CTS.CRY.V03. Design envelopes do not represent a guaranteed operating point. Allowable pressure ratings depend on valve size, end connection, seat material, and operating temperature.

3-Piece Body
Design and Port
3-piece, floating, unidirectional. Full port ½″ to 6″.
Nominal Pressure Class
Class 600, 300, or 150 depending on size
Design Temperature
-196 to +200 °C

Flanged body
Design and Port
Two-piece body, flanged. Full bore ½″ to 6″.
Nominal Pressure Class
Class 150 or 300
Design Temperature
-196 to +200 °C
UNDERSTANDING VALVE DESIGN & CONSTRUCTION
The VINCO cutaway view illustrates both the open and closed positions, providing a clear understanding of the ball's travel and positioning while accurately reflecting the valve's mechanical design.

Official VINCO cross-section · Catalogue CTS.CRY.V03, page 7. Manufacturer's conceptual schematic; non-binding for any specific dimension.
The extension creates a vapour column between the cryogenic liquid and the stem packing. Both length and mounting orientation are critical factors in the selection process.
An upstream relief vent mitigates overpressure caused by thermal expansion of trapped liquid, requiring strict adherence to the indicated flow direction.
The tongue-and-groove connection between the ball and stem, along with clear directional markings, ensures accurate reassembly. Proper ball orientation is critical and cannot be left to chance.
CONFIGURE YOUR SELECTION
LNG, liquid nitrogen, gas, or gas mixtures. For oxygen service, further define cleanliness levels, degreasing specifications, and approved materials.
CF3M stainless steel CXF with threaded or welded ends depending on configuration. Flanged ASME CCF in CF8M. TFM1600 seats, with a PCTFE option available based on project specifications.
Please specify the required cryogenic testing, fail-safe position, and cold torque conditions for the actuator. The ISO 5211 interface alone is insufficient for proper sizing.
The catalogue provides for cryogenic testing in accordance with BS 6364 upon request and references ISO 28921-2. The test procedure, test temperature, and required certification must be specified on the purchase order. CRN eligibility must be verified for the specific part number and target province.
APPLICATIONS & ENGINEERING GUIDE
VINCO provides dedicated data sheets for LNG and liquid CO₂. The specific fluid and service conditions determine the required configuration.
LNG · VINCO APPLICATION
LNG combines extremely low temperatures with high flammability. Proper cryogenic valve selection focuses on sealing integrity, cavity pressure relief, and piping line configuration.
LIQUID CO₂ · SPECIALIZED SERVICE
Rapid depressurization, positive shut-off, and cavity relief are critical to this service. Selection aligns with the VINCO CO₂ technical datasheet specifications, featuring a configuration tailored specifically to the media.
TECHNICAL INQUIRIES
MANUFACTURER DOCUMENTATION
These documents facilitate the selection process. The proposed configuration data sheet and its associated certificates complete the order package.

SERVING QUEBEC AND CANADA
Looking to replace an existing unit or planning a new installation? Share your operating conditions to get your tailored VINCO selection underway.
Materials, seating, and actuation engineered to meet your specific operating conditions.
Part number, options, availability, and lead time specified in your quote.
Technical data sheets, drawings, and required documentation consolidated to match your project specifications.