No. The product line distinguishes between high-temperature and abrasive service configurations. The XFM-A is rated up to 250°C, while the XFM-T and CFM-T are engineered to handle up to 450°C in the configurations specified by VINCO.
VINCO · Metal-Seated Valves

XFM-T · High Temperature
XFM-T · High Temperature
XFM-A · Abrasion
CFM-T · Flanged
COMPARE SERIES
The upper limits listed below are specified by VINCO. Pressure class, coating, and maximum allowable assembly temperature must be verified against the proposed configuration datasheet.

High Temperature
Construction
3-piece, metal-seated, unidirectional.
Specified upper limit
Up to +450 °C
Intended Application
High-temperature service.

High-Temperature Flanged
Construction
Two-piece body, flanged, metal-seated.
Specified upper limit
Up to +450 °C
Intended Application
Flanged inline high-temperature service.

Abrasive Service
Construction
3-piece, metal-seated, bidirectional.
Specified upper limit
Up to +250 °C
Intended Application
Abrasive service.
UNDERSTANDING VALVE DESIGN & CONSTRUCTION
The ball and seats form a mating surface pair where coating, fit, and operational loads directly impact wear, operating torque, and seat leakage.

VINCO XFM Series · Official rendering. Coating and trim specifications are determined by the selected model.
Verify normal, maximum, and start-up temperatures, thermal cycling, as well as the operating limits of the seals, packing, and actuator.
Specify the type, hardness, size, and concentration of solids. The presence of particulate alone is insufficient to select a coating or guarantee service life.
Metal-to-metal sealing does not imply zero leakage. The allowable leakage rate, test procedure, and installation direction must be clearly specified.
CONFIGURE YOUR SELECTION
Fluid, continuous and peak temperatures, concurrent pressure, thermal cycling, and potential presence of condensate.
Solids loading, particle size distribution, velocity, cycling frequency, and throttling conditions.
Breakaway torque, cycle frequency, closing time, and fail-safe position. An adequate service safety margin is required for reliable actuation.
The manufacturer's XFM data sheets cite EN 12266-1 / ISO 5208 / API 598 testing with a Rate D leakage rate. The contractual acceptance criteria must be confirmed on the quotation. Fire-safe qualification does not establish standard operating temperatures.
METAL SEAT APPLICATIONS
The XFM-T and CFM-T series are engineered for high-temperature applications, while the XFM-A is designed specifically for abrasive media. Optimal selection depends on your process fluid and actual operating conditions.
XFM-T · CFM-T
Selection factors in the pressure-temperature envelope, thermal cycling, process media, and allowable seat leakage.
XFM-A
VINCO introduces this series engineered for abrasive media. Particle composition and concentration, as well as operating pressure and temperature, must be specified to tailor the optimal configuration.
TECHNICAL INQUIRIES
MANUFACTURER DOCUMENTATION
These documents facilitate the selection process. The proposed configuration data sheet and its associated certificates complete the order package.

SERVING QUEBEC AND CANADA
Looking to replace an existing unit or planning a new installation? Share your operating conditions to get your tailored VINCO selection underway.
Materials, seating, and actuation engineered to meet your specific operating conditions.
Part number, options, availability, and lead time specified in your quote.
Technical data sheets, drawings, and required documentation consolidated to match your project specifications.