VINCO · Metal-Seated Valves

VINCO Metal-Seated Valves

VINCO Metal-Seated Valves

VINCO Metal-Seated Valves

High temperatures and severe abrasion demand distinct engineered solutions. VINCO differentiates with XFM-T and CFM-T constructions for thermal service, and XFM-A for abrasive applications.

High temperatures and severe abrasion demand distinct engineered solutions. VINCO differentiates with XFM-T and CFM-T constructions for thermal service, and XFM-A for abrasive applications.

VINCO Metal-Seated Valves

XFM-T · High Temperature

XFM-T · High Temperature

XFM-A · Abrasion

CFM-T · Flanged

COMPARE SERIES

Heat and Abrasion: Two Distinct Demands

Heat and Abrasion: Two Distinct Demands

Heat and Abrasion: Two Distinct Demands

The upper limits listed below are specified by VINCO. Pressure class, coating, and maximum allowable assembly temperature must be verified against the proposed configuration datasheet.

Official image of the VINCO XFM-T metal-seated valve

High Temperature

XFM-T

XFM-T

Construction

3-piece, metal-seated, unidirectional.

Specified upper limit

Up to +450 °C

Intended Application

High-temperature service.

Official image of the flanged VINCO CFM-T

High-Temperature Flanged

CFM-T

CFM-T

Construction

Two-piece body, flanged, metal-seated.

Specified upper limit

Up to +450 °C

Intended Application

Flanged inline high-temperature service.

Official image of the VINCO XFM-A metal-seated valve

Abrasive Service

XFM-A

XFM-A

Construction

3-piece, metal-seated, bidirectional.

Specified upper limit

Up to +250 °C

Intended Application

Abrasive service.

UNDERSTANDING VALVE DESIGN & CONSTRUCTION

A metal seat does not eliminate operating limits

A metal seat does not eliminate operating limits

A metal seat does not eliminate operating limits

The ball and seats form a mating surface pair where coating, fit, and operational loads directly impact wear, operating torque, and seat leakage.

VINCO XFM Series · Official visual. Lining and trim are specified according to the proposed configuration.

VINCO XFM Series · Official rendering. Coating and trim specifications are determined by the selected model.

Heat

Heat

Verify normal, maximum, and start-up temperatures, thermal cycling, as well as the operating limits of the seals, packing, and actuator.

Particulate Matter

Particulate Matter

Specify the type, hardness, size, and concentration of solids. The presence of particulate alone is insufficient to select a coating or guarantee service life.

Sealing and Flow Direction

Sealing and Flow Direction

Metal-to-metal sealing does not imply zero leakage. The allowable leakage rate, test procedure, and installation direction must be clearly specified.

CONFIGURE YOUR SELECTION

The insights that make the difference

The insights that make the difference

The insights that make the difference

For High-Temperature Applications

For High-Temperature Applications

Fluid, continuous and peak temperatures, concurrent pressure, thermal cycling, and potential presence of condensate.

For abrasive service

For abrasive service

Solids loading, particle size distribution, velocity, cycling frequency, and throttling conditions.

To Order

To Order

Breakaway torque, cycle frequency, closing time, and fail-safe position. An adequate service safety margin is required for reliable actuation.

Testing and compliance specifications to be confirmed

Testing and compliance specifications to be confirmed

The manufacturer's XFM data sheets cite EN 12266-1 / ISO 5208 / API 598 testing with a Rate D leakage rate. The contractual acceptance criteria must be confirmed on the quotation. Fire-safe qualification does not establish standard operating temperatures.

METAL SEAT APPLICATIONS

High Temperature and Abrasion: Selecting the Right Valve Solution for Your Service.

High Temperature and Abrasion: Selecting the Right Valve Solution for Your Service.

High Temperature and Abrasion: Selecting the Right Valve Solution for Your Service.

The XFM-T and CFM-T series are engineered for high-temperature applications, while the XFM-A is designed specifically for abrasive media. Optimal selection depends on your process fluid and actual operating conditions.

XFM-T · CFM-T

High-Temperature Service

High-Temperature Service

Selection factors in the pressure-temperature envelope, thermal cycling, process media, and allowable seat leakage.

XFM-A

Abrasive Fluids

Abrasive Fluids

VINCO introduces this series engineered for abrasive media. Particle composition and concentration, as well as operating pressure and temperature, must be specified to tailor the optimal configuration.

TECHNICAL INQUIRIES

Key parameters to address prior to selection.

Key parameters to address prior to selection.

Key parameters to address prior to selection.

MANUFACTURER DOCUMENTATION

Consult VINCO resources.

Consult VINCO resources.

Consult VINCO resources.

These documents facilitate the selection process. The proposed configuration data sheet and its associated certificates complete the order package.

VAMECA · Technical and Commercial Support

SERVING QUEBEC AND CANADA

The right construction engineered for your service.

The right construction engineered for your service.

The right construction engineered for your service.

Looking to replace an existing unit or planning a new installation? Share your operating conditions to get your tailored VINCO selection underway.

Partnering with you to drive your operations forward

Partnering with you to drive your operations forward

Tailored Selection

Tailored Selection

Materials, seating, and actuation engineered to meet your specific operating conditions.

Coordinated Procurement

Coordinated Procurement

Part number, options, availability, and lead time specified in your quote.

A project specification developed collaboratively with you

A project specification developed collaboratively with you

Technical data sheets, drawings, and required documentation consolidated to match your project specifications.