INDUSTRIAL GASKETS & SEALING SOLUTIONS

INDUSTRIAL GASKETS & SEALING SOLUTIONS

LATTY

LATTY

LATTY

LATTYgraf HPML NUC

LATTYgraf HPML NUC

LATTYgraf HPML NUC

LATTYgraf HPML NUC is a variant in the HPML line, engineered with multi-layer stainless steel-reinforced expanded graphite and formulated to meet the rigorous demands of the nuclear industry.

Our Quebec facility manufactures custom-cut flat gaskets to your exact specifications. VAMECA can also evaluate the supply of this part number or engineer a suitable replacement.

AT A GLANCE

Multi-layer graphite

Product Family

Graphite

Material Composition

> 99% expanded graphite, multi-layer stainless steel, oxidation inhibitor

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Material Specifications

Material Specifications

Maximum temperature and pressure limits cannot be applied simultaneously.

TEMPERATURE

Min. -200 °C · Max. catalog 550 °C · Inert 700 °C

PRESSURE

250 bar (catalogue maximum, verify according to P/T rating)

THICKNESSES

1.0 / 1.5 / 2.0 / 3.0 / 4.0 mm

Applications and Key Features

LATTY's supplier approval covers static sealing solutions engineered for environments with rigorous documentation requirements. Specific applications and qualifications must be defined in accordance with NUC-grade documentation.

PART NUMBER ANALYSIS

To properly select or replace this material

To properly select or replace this material

To properly select or replace this material

01 · What Sets This Material Apart

Nuclear-grade designation alone does not constitute qualification, customer approval, or project-specific certification. Verification matching the exact style is required.

02 · Operating Conditions to Consider

Listing by LATTY applies to static sealing solutions for environments with stringent documentation requirements. Applications and qualifications must be determined based on NUC-grade documentation.

03 · Prior to Replacement

Verify the construction code, quality assurance requirements, traceability, customer specifications, and service conditions before recommending the grade.

Cross-references to evaluate: LATTYgraf HPML, TEADIT GR 1700, and Garlock GRAPH-LOCK 3128. These comparisons do not validate direct substitution.

REPLACEMENT TO BE EVALUATED

REPLACEMENT TO BE EVALUATED

Compare designs and alternatives

Compare designs and alternatives

KEY COMPARISON CRITERIA

The NUC suffix must be maintained: a standard HPML is not automatically interchangeable with a nuclear-grade version.

Need this gasket, custom cutting, or a replacement?

Part Number: LATTYgraf HPML NUC

Please provide the part number, thickness, dimensions, quantity, and process fluid. We will review material availability for the specified grade, custom cutting at our Quebec facility, or an engineered alternative tailored to your assembly.

View official documentation

View official documentation

The manufacturer's latest datasheets, certifications, and P/T curves must be reviewed prior to ordering or substitution.

RELATED PART NUMBERS

RELATED PART NUMBERS

Compare Related Designs

Compare Related Designs

Multi-layer graphite to be verified for construction purposes only. Any nuclear or PMUC requirements necessitate a dedicated certificate.

REFERENCE SHEET

TEADIT

Multi-layer reinforced flexible graphite

REFERENCE SHEET

Garlock

Multilayer flexible graphite with 316 stainless steel foil inserts

VAMECA · Industrial Valves and Sealing Solutions · Quebec / Canada